Boon Edam 1002171 Sensor Transmitter, Multibeam
Sign In for Dealer Pricing
SAE SSU-55000-335DCT Duct Smoke Detector Replacement Head
Sign In for Dealer Pricing
sae smoke detector image of o6-ssusm501p
Sign In for Dealer Pricing
duct detector air velocity anemometer image of 2s-av02
Sign In for Dealer Pricing
SAE FE-6030-300 Fireray Hub Reflective Detector
Sign In for Dealer Pricing
System Sensor OSI-R-SS Reflected Type Beam Smoke Detector, 4-Wire, Single-Ended, 8" Reflector and Integral Sensitivity Test, (Replaces BEAM1224)
OSI-R-SS4H-OSIR

Key Features

  • Combined transmitter/receiver unit
  • Wide 12° field of view
  • Fast, easy, and intuitive beam alignment indicated by directional LED cross-hair arrows
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Fire-Lite OSI-RI-FL Intelligent Addressable Reflector-Type Linear Optical Beam Smoke Detector, UL/ULC listed
OSI-RI-FL8K-OSIRIFL

Key Features

  • Fast and easy alignment
  • Resistant to building movement
  • Resistant to sunlight
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Fire-Lite D365PL Intelligent Non-Relay Photoelectric Duct Smoke Detector
8K-D365PL8K-D365PL

Key Features

  • Photoelectric, integrated low-flow technology
  • Air velocity rating from 100'/min – 4,000'/min (0.5 m/s – 20.32 m/s)
  • Broad ranges for operating temperature (-4°F – 158°F, -20°C – 70°C) and humidity (0% – 93% non-condensing)
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Boon Edam 1002171 Sensor Transmitter, Multibeam
1002171BP-1002171
Sign In for Dealer Pricing
Sign In for Dealer Pricing
SAE SSU-55000-335DCT Duct Smoke Detector Replacement Head
SSU-55000-335DCTO6-SSU5535CT

Key Features

  • Photoelectric replacement sensor for duct smoke detectors
  • Compatible with RT-3000-P, SL-2000-P, and SM-501-P models
  • Model number SSU-55000-335DCT
Sign In for Dealer Pricing
Sign In for Dealer Pricing
System Sensor D4240 4-Wire Photoelectric Duct Smoke Detector
D42404H-D4240

Key Features

  • Photoelectric, integrated low-flow technology
  • Air velocity rating from 100'/min to 4,000'/min (0.5 m/s to 20.32 m/sec)
  • Versatile mounting options: square or rectangular configuration
Sign In for Dealer Pricing
Sign In for Dealer Pricing
system sensor innovairflex d4120w smoke detector image of 4h-d4120w;system sensor d4120w watertight 4-wire photoelectric duct smoke detector image of 4h-d4120w;system sensor d4120w watertight 4-wire photoelectric duct smoke detector image of 4h-d4120w
D4120W4H-D4120W

Key Features

  • NEMA Type 4 UL listed for non-hazardous indoor and outdoor applications
  • 4-Wire Photoelectric, integrated low-flow technology
  • UV Resistant, UL listed housing and cover materia
Sign In for Dealer Pricing
Sign In for Dealer Pricing
sae smoke detector image of o6-ssusm501p
SSU-SM-501-PO6-SSUSM501P

Key Features

  • Ionization and Photoelectric versions available (ionization version availability is limited)
  • Both models listed for high temperature applications
  • Interconnect up to 30 units for common functions
Sign In for Dealer Pricing
Sign In for Dealer Pricing
STI KIT-R08604 Replacement Duct Smoke Detector Filters, Pack of 3
KIT-R08604SF-KITR0804

Key Features

  • For use with EnviroArmour Waterproof Enclosures
  • Replacement filters for NEMA 3R filter fan with vent
Sign In for Dealer Pricing
Sign In for Dealer Pricing
sae ssu-sl-2000-p smoke setector image of o6-sl2000p
SSU-SL-2000-PO6-SL2000P

Key Features

  • Low-Flow Technology: Both Ionization and Photoelectric models listed for velocities between 100-4000'/min
  • Both models listed for high-temperature applications
  • UL, CUL, CSFM, and MEA Listed
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Fire-Lite D365PL Intelligent Non-Relay Photoelectric Duct Smoke Detector
D365PLFL-D365PL

Key Features

  • Photoelectric, integrated low-flow technology
  • Air velocity rating from 100'/min – 4,000'/min (0.5 m/s – 20.32 m/s)
  • Broad ranges for operating temperature (-4°F – 158°F, -20°C – 70°C) and humidity (0% – 93% non-condensing)
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Potter PAD 200-DD Analog Addressable Duct Detector
PAD 200-DDPL-PAD200DD

Key Features

  • Legacy Unit; Latest Model is PAD300-DD
  • Detects smoke in building HVAC ducts Ships complete with housing and heaD
  • Ships complete with housing and head
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of ed-sdgsk
SD-GSKED-SDGSK

Key Features

  • Less than 2" deep for easy installation and applications where space is tight
  • PCB mounted photoelectric sensor with on-board inteliigence
  • Environmental compensation with patented differential sensing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Edwards Signaling EC5000R Self Adjusting Reflective Beam Detector, 160-330'
EC5000RED-EC5000R

Key Features

  • Coverage: 50R range 15 - 160 ft (4.6 - 48.8m); 100R range 160 - 330 ft (48.8 - 100m)
  • Microprocessor controlled
  • Automatic drift compensation
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Secutron MIX-4010-DUCT 4000 Series Intelligent Photoelectric Duct Smoke Detector, Includes Head
MIX-4010-DUCT5T-MIX4010DT

Key Features

  • Smoke Detector head (MIX-4010-D) included
  • Clear cover allowing visual inspection
  • Designed to optimize the air flow on the smoke detector
Sign In for Dealer Pricing
Sign In for Dealer Pricing
utc fire & security intelligent superduct detector image of ed-gsasd
GSA-SDED-GSASD

Key Features

  • Less than 2″ deep for easy installation and applicationsWhere space is tight
  • -4°F to 158°F (-20°C to 70°C) operating range with 100'/min. to 4,000'/min air velocity rating assures reliability under harsh environmental conditions
  • Status LEDs remain visible through clear assembly cover
Sign In for Dealer Pricing
Sign In for Dealer Pricing
edwards signaling intelligent addressable duct smoke detector image of ed-fxpdd
FX-PDDED-FXPDD

Key Features

  • Less than 2" deep for easy installation and applicationsWhere space is tight
  • Status LEDs remain visible through clear assembly cover
  • Standard sAling tube spacing for easy drop-in migration from other detectors
Sign In for Dealer Pricing
Sign In for Dealer Pricing
duct detector air velocity anemometer image of 2s-av02
AV022S-AV02

Key Features

  • Ensures duct detector will sample the air velocity correctly
  • Easy to use
  • Includes meter, telescopic probe, USB cable, PC interface software, AC adaptor, and hard case
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Silent Knight DNR Intelligent Photoelectric Duct Detector 100 to 4000', 0.73Kg
DNR9R-DNR

Key Features

  • Photoelectric, integrated low-flow technology
  • Patented sampling tube installs from front or back of the detector with no tools required
  • Easily accessible code wheels on sensor head (sold separately)
Sign In for Dealer Pricing
Sign In for Dealer Pricing
system sensor innovairflex d4s smoke detector sensor component image of 4h-d4s;system sensor d4s 4-wire photoelectric sensor component image of 4h-d4s;system sensor d4s 4-wire photoelectric sensor component image of 4h-d4s
D4S4H-D4S

Key Features

  • 4-Wire Photoelectric, integrated low-flow technology
  • Air velocity rating from 100'/min to 4,000'/min (0.5 m/s to 20.32 m/sec)
  • Versatile mounting options: square or rectangular configuration
Sign In for Dealer Pricing
Sign In for Dealer Pricing
SAE FE-1010-000 Fireray One Self-Aligning Beam Smoke Detector
FE-1010-000O6-FE1010000

Key Features

  • One Minute Auto-Alignment – just steer the laser onto the Reflector, then at the flick of a switch, it aligns itself. 8 times faster than previous detectors
  • One person installation – everything can be done by one person
  • One standalone product – no specialist tools required; minimal prior knowledge and training needed
Sign In for Dealer Pricing
Sign In for Dealer Pricing
SAE FE-6030-300 Fireray Hub Reflective Detector
FE-6030-300O6-FE6030300
Sign In for Dealer Pricing
Sign In for Dealer Pricing
silent knight osi-ri-sk intelligent single-ended reflective imaging beam smoke detector image of 9r-osirisk
OSI-RI-SK9R-OSIRISK

Key Features

  • Fast and Easy Alignment
  • Resistant to Building Movement, Sunlight, and Foreign Object Intrusion
  • Time-saving Automatic Sensitivity Setting
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Kidde KIR-DDOS Optica Intelligent Duct Smoke Detector Rotary Addressed
KIR-DDOSED-KIRDDOS

Key Features

  • Less than 2.5" deep for easy installation and applications where space is tight
  • -20°F to 158°F (-29°C to 70°C) operating range with 100 ft/min to 4,000 ft/min air velocity rating assures reliability under harsh environmental conditions
  • Standard sampling tube spacing for easy drop-in migration from other detectors
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Silent Knight DNRW Innovairflex Duct Detector, Non-Relay, Watertight
DNRW9R-DNRW

Key Features

  • Photoelectric, integrated low-flow technology
  • Air velocity rating from 100 ft/min – 4,000 ft/min (0.5 m/s – 20.32 m/s)
  • Versatile mounting options: square or rectangular configuration
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Silent Knight SK-DUCT-W Intelligent Photoelectric Duct Smoke Detector, Smoke Detector Housing and SK-PHOTO-R-W Detector
SK-DUCT-W9R-SKDUCTW

Key Features

  • Photoelectric, integrated low-flow technology
  • Air velocity rating from 100'/min – 4,000'/min (0.5 m/s – 20.32 m/s)
  • Broad ranges for operating temperature (-4°F – 158°F, -20°C – 70°C) and humidity (0% – 93% non-condensing)
Sign In for Dealer Pricing
Sign In for Dealer Pricing
system sensor d4120 4-wire photoelectric low-flow duct smoke detector, replaces dh100acdclp image of 4h-d4120;system sensor d4120 4-wire photoelectric low-flow duct smoke detector, replaces dh100acdclp image of 4h-d4120;system sensor d4120a 4-wire duct detector, 24vdc/120vac image of 4h-d4120;system sensor d4120 4-wire photoelectric low-flow duct smoke detector, replaces dh100acdclp image of 4h-d4120
D41204H-D4120

Key Features

  • 4-Wire Photoelectric, integrated low-flow technology
  • Versatile mounting options: square or rectangular configuration
  • Increased wiring space with a newly added ¾" conduit knockout
Sign In for Dealer Pricing
Sign In for Dealer Pricing
system sensor innovairflex d2 smoke detector image of 4h-d2;system sensor d2 2-wire photoelectric duct smoke detector image of 4h-d2;system sensor d2 2-wire photoelectric duct smoke detector image of 4h-d2;system sensor d2 2-wire photoelectric duct smoke detector image of 4h-d2
D24H-D2

Key Features

  • Photoelectric, integrated low-flow technology
  • Versatile mounting options in square or rectangular configuration
  • Increased wiring space with a newly added ¾ inch conduit knockout
Sign In for Dealer Pricing