adi-insite-pr
ADI a Resideo company
menu

Fire-Lite Alarms by Honeywell

Filter Results

Applied Filters
Fire Control Panels
Showing  1 - 28 of 85
content loaded
image of 8k-es200x
ES-200X8K-ES200X

Key Features

  • Upload/Download panel programming database and flash firmware with USB thumb drive
  • Addressable multi-criteria detector (smoke, heat, CO) with programmable response
  • Addressable Sounder Bases
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of 8k-crf300
CRF-3008K-CRF300

Key Features

  • 16 to 32V DC
  • Built-in type identification automatically identifies these devices to the control panel
  • Internal circuitry and relay powered directly by two-wire SLC loop
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of 8k-es50x
ES-50X8K-ES50X

Key Features

  • Upload/Download panel programming database and flash firmware with USB thumb drive
  • Addressable multi-criteria detector (smoke, heat, CO) with programmable response
  • Addressable Sounder Bases
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Fire-Lite SLC-3LS Optional Loop Expander Card
SLC-3LS8K-SLC3LS

Key Features

  • Optional loop expander card for ES-1000X Series
  • Adds additional SLC communication loops
  • Supports up to 318 devices per card
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of 8k-es1000x;image of 8k-es1000x;image of 8k-es1000x
ES-1000X8K-ES1000X

Key Features

  • Supports up to 954 devices for larger and more complex installations
  • Single SLC that provides support for up to 318-Addressable devices (159-Detectors and 159-Modules) per SLC with maximum 3-Loops
  • Built-in dual-path communicator (POTS and IP)
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of fl-mrp2002
MRP-2002FL-MRP2002

Key Features

  • Meets International Building Code IBC seismic requirements
  • Adjustable pre-discharge, discharge and waterflow delay timers.
  • Dual hazard operation
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of 8k-ann80
ANN-808K-ANN80

Key Features

  • Backlit 80-character LCD (20 characters x 4 lines) mimics all display information from the host panel
  • Control switches for system acknowledge, signal silence, drill, and reset
  • Keyswitch enables/disables control switches, mechanically locks annunciator enclosure, and can be enabled or disabled at the FACP
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of 8k-lcd80f
8K-LCD80F8K-LCD80F

Key Features

  • Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs
  • Can be located up to 6,000' (1,800 m) from the panel
  • Plug-in terminal blocks for ease of installation and service
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of 8k-mmf301
MMF-3018K-MMF301

Key Features

  • 15-32V DC
  • Supervises a Style B (Class B) circuit of dry-contact input devices
  • Compact design allows mounting in a single-gang box behind the device it monitors
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of 8k-mcbl7
MCBL-78K-MCBL7

Key Features

  • This phone cable provides splendid performance and clear connectivity
  • Fully compatible with phones
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of 8k-mmf300
MMF-3008K-MMF300

Key Features

  • 15 to 32V DC
  • Built-in type identification automatically identifies this device as a monitor module to the control panel.
  • Powered directly by two-wire SLC loop. No additional power required.
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of 8k-cmf300
CMF-3008K-CMF300

Key Features

  • CMF-300 may be used to switch 24V NAC power
  • A trouble condition on the external power supply will never interfere with the rest of the system
  • Built-in type identification automatically identifies this device to the control panel
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of fl-dp51050
DP-51050FL-DP51050

Key Features

  • Mounts inside the cabinet and trim-ring
  • For use with Fire-Lite MS-5UD/MS-10UD Series fire alarm control panels (FACPs)
Sign In for Dealer Pricing
Sign In for Dealer Pricing
fire-lite ann-led annunciator module
ANN-LEDFL-ANNLED

Key Features

  • ANN-LED connects to the ANN-Bus terminal on the FACP and required minimal programming
  • Includes three LEDs for each zone Alarm, Trouble, and Supervisory
  • Can be remotely located up to 6,000' (1,829 m) from the panel
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of fl-annsec
ANN-SECFL-ANNSEC

Key Features

  • Used only with firmware 3.0 or higher on MS-9050UD(E) Fire Alarm Control Panel with DACT
  • Optional secondary ANN-BUS interface module
  • The ANN-SEC comes with all hardware required to mount to the Control Panel
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of fl-eccce4
ECC-CE4FL-ECCCE4

Key Features

  • The ECC-CE4 mounts inside the ECC-50/125DA(E) cabinet
  • Compatible with the Fire-lite ECC-50/100 Emergency Co mmand Center and their remote Alifiers
  • Modular design for system flexibility and easy expansion
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of fl-eccce6
ECC-CE6FL-ECCCE6

Key Features

  • Circuits are Configured Through theWeb-Based Progra mming Utility
  • Removable terminal blocks for ease of servicing and module replacement
  • Modular design for system flexibility and easy expansion
Sign In for Dealer Pricing
Sign In for Dealer Pricing
fire-lite ann-sb80kit-w wall mount - white
ANN-SB80KIT-WFL-ANSB80KTW

Key Features

  • Control switches can be independently enabled or disabled at the FACP
  • Keyswitch enables/disables control switches and mechanically locks annunciator enclosure
  • Enclosure supervised for tamper
More Options Available
Sign In for Dealer Pricing
More Options Available
Sign In for Dealer Pricing
image of fl-annspg
ANN-S/PGFL-ANNSPG

Key Features

  • Auto-configure menu selection allows progra mmer to bring all the devices attached to the ANN-BUS on-line quickly.
  • Surface mounts directly toWall.
  • Can be remotely located up to 6,000' (1,829 m) from the panel.
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of fl-pro411
PRO-411FL-PRO411

Key Features

  • Three (411) or four (411UD) monitoring channels (inputs)
  • Inputs may be individually programmed to monitor host control panels
  • Fully supervised trigger inputs require a contact closure for activation
Sign In for Dealer Pricing
Sign In for Dealer Pricing
fire-lite w-gate swift wireless gateway
W-GATEFL-WGATE

Key Features

  • Wireless mesh technology (902-928 MHz frequency)
  • Cascading-wave mesh operation provides a verification of redun-dant communication paths
  • AnyWireless device can be added to act as a repeater
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of fl-ms5ud3e;image of fl-ms5ud3e
MS-5UD-3EFL-MS5UD3E
Sign In for Dealer Pricing
Sign In for Dealer Pricing
fire-lite led interface module - 4xlmf
4XLMFFL-4XLMF

Key Features

  • Maximum voltage/current, each output: 27.6 V / 8 mA.
  • Outputs are power-limited.
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of fl-ansb80ktr
ANN-SB80KIT-RFL-ANSB80KTR

Key Features

  • Mimics all display information from the host panel
  • Control switches for system acknowledge, signal silence, drill, and reset
  • Control switches can be independently enabled or disabled at the FACP
More Options Available
Sign In for Dealer Pricing
More Options Available
Sign In for Dealer Pricing
fire-lite firewatch 411 fire alarm control/communicator
411FL-411

Key Features

  • Trigger inputs require a contact closure for activation
  • Inputs may be individually programmed to monitor the host control panel
  • Includes 15 reporting formats, including the popular ADEMCO Contact ID format
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of fl-eccxrm70v
ECC-XRM-70VFL-ECCXRM70V

Key Features

  • Converts the ECC-50/100 Emergency Co mmand Center from a 25V system to a 70V system
  • Must be mounted in conjunction with ECC-CE6 if used in a system with circuit expander
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of fl-annrly;image of fl-annrly
ANN-RLYFL-ANNRLY

Key Features

  • ANN-RLY connects to the ANN-BUS terminal on the FACP and requires minimal programming
  • Provides 10-programmable Form-C relays
  • Ten Form-C relays can be programmed for various functions; Alarm, Trouble, Supervisory, AC Loss,Waterflow Delay, Input Zones and Silenceable Alarm
Sign In for Dealer Pricing
Sign In for Dealer Pricing
image of fl-411udac
411UDACFL-411UDAC

Key Features

  • Dual telephone line voltage detect
  • Signal Silence Inhibit
  • 1.6 As total system power
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Showing 1 - 28 of 85
Sign Up for Email
Sign Up
Branch
Locator

© 2026 ADI Global - All Rights Reserved.