Introducing the Altronix EFLOW4NA8V Access Power Controller, designed to efficiently manage power for your access control systems and accessories. This robust unit transforms a 220V AC input into eight independently controlled, fuse-protected outputs, delivering a total of 4A continuous supply current at either 12V DC or 24V DC. With versatile activation options, it seamlessly integrates with various access control devices such as mag locks and electric strikes, operating in both fail-safe and fail-secure modes. The FACP interface supports emergency egress and alarm monitoring, ensuring safety and reliability. Upgrade your security system today with the Altronix EFLOW4NA8V!
Specifications
ADI Part Number AX-EFLOWNA8V Brand Name Altronix Manufacturer Altronix Corporation Manufacturer Part Number EFLOW4NA8V Product Line eFlow Product Model EFLOW4NA8V Product Name Access Power Controller With Power Supply/Charger, 8 Fused Relay Outputs, 12/24VDC, 4A, Aux Output, FAI, 220VAC, BC400 Enclosure Product Type Access Power Controller Sector Access Control
Number of Doors 8 Output Voltage 12V DC, 24V DC
NDAA Compliant Yes
Operating Temperature (T-T) 32-120°F Storage Temperature (T-T) -4-158°F
Depth 4.5" Height 15.5" Weight 8.65lb Width 12"
Input Voltage 220V AC
Limited Warranty Lifetime
Environmental Certification RoHS Features AC fail supervision (form "C" contacts), Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL), Automatic switch over to stand-by battery when AC fails. Transfer to stand-by battery power is instantaneous with no interruption, Battery fail & presence supervision (form "C" contacts), Built-in charger for sealed lead acid or gel type batteries, Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs, Low power shutdown. Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge, Normally open (NO) or normally closed (NC) dry contact input, Polarity reversal input from FACP signaling circuit, Zero voltage drop when unit switches over to battery backup (AC failure condition) Indoor/Outdoor Indoor