Macurco
Filter Results
Showing 1 - 28 of 108
content loaded
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
37-0450-4134-2|MA-NDGASCYLI
Sign In for Dealer Pricing
More Options Available
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
88-C50I-0000-00|MG-88C50I000
Sign In for Dealer Pricing
Emergency Stop Button|MA-702900058
Sign In for Dealer Pricing
Sign In for Dealer Pricing
70-2900-0541-2|MG-702900054
Sign In for Dealer Pricing
Sign In for Dealer Pricing
AS-A11-740-000-B|MA-ASA11740000B
Sign In for Dealer Pricing
CO2 5% VOL|MA-702900030
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Easy installation to 4x4 electrical boxes via mud plate
- User selectable settings (Default to industry standards) via two button interface
- 5 A SPDT fan relay, 0.5A alarm relay to control fans, valves, louvers, horn and strobes
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Calibration Hood
- For Use With CM-6 and CM-12 Gas Detectors
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Easy installation to 4x4 electrical boxes via mud plate
- User selectable settings (Default to industry standards) via two button interface
- 5 A SPDT fan relay, 0.5A alarm relay to control fans, valves, louvers, horn and strobes
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Digital Display (0-200ppm of CO), Onboard buzzer
- 100-240VAC input
- 5A SPDT Fan Control Relay
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Gases Ordered Separately
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Retrofits 2-gang to single gang installations
- Compatible with CM-15, CM-15A, CM-16A
- Designed for CM-E1 detectors
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Used with Macurco Cal-Kit 4
- Works with CD-6H, CD-12H, CD-6MC, CD-12MC, CD-6B, CD-6G
- Size: 10.6" x 3.1" x 3.1" (27 x 7.9 x 7.9 cm)
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Used with Macurco Cal-Kit 1
- Works with GD-6, GD-12
- Size: 10.6" x 3.1" x 3.1" (27 x 7.9 x 7.9 cm)
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- 12-24V AC or 12-32V DC input
- 5A SPDT Fan control relay
- 0.5A N.O. or N.C. Alarm Relay
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- The Macurco MRS-485 interfaces the detector power and 4-20mA output lines with a mounted connector The MRS-485 monitors sensor type, gas level and trouble status communications from any of the Macurco 6-Series detectors
- communication is on a Modbus serial line Co mmercial type enclosure to protect and support the electronics
- Tricolor LED indicates power, test and communication status
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- 12-24V AC or V DC input
- Flush or Surface Mount Enclosure
- N.O. or N.C. Alarm Relay
Sign In for Dealer Pricing
Sign In for Dealer Pricing
37-0450-4134-2|MA-NDGASCYLI
Key Features
- Used with Macurco Cal-Kit 2
- Works with CX-6, CX-12, TX-6-ND, TX-12-ND
- Size: 10.6" x 3.1" x 3.1" (27 x 7.9 x 7.9 cm)
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Flexible optic design to meet or exceed the light output on vertical/horizontal dispersion
- Strobe Candela: Adjustable at 15, 30, 75 or 110cd
- Adjustable two audible tone settings: Continuous (high/low) / Temporal 4 (high/low)
More Options Available
Sign In for Dealer Pricing
More Options Available
Sign In for Dealer Pricing
Key Features
- 16 to 33 VDC
- Strobe Candela: Adjustable at 15, 30, 75 or 110cd* (tested with clear lens cover)
- Audible Tone: Adjustable to Continuous (high/low) or Temporal Four (high/low)
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Sign In for Dealer Pricing
88-C50I-0000-00|MG-88C50I000
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Emergency Stop Button|MA-702900058
Key Features
- Optional LED 12-24V
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- 17 to 33 VDC
- Strobe Candela: Adjustable at 15, 30, 75 or 110cd* (tested with clear lens cover)
- Strobe Flash Rate: One flash per second (20ms pulse duration)
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Modbus addressable relay
- 24 VDC input
- 4 expansion slots for expansion boards: up to 8 relays, 8 analog outputs, or 12 analog inputs
Sign In for Dealer Pricing
Sign In for Dealer Pricing
70-2900-0541-2|MG-702900054
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Shutdown up to 8 boilers individually via expansion relays
- 24VAC/VDC
- Customize up to 8 10A SPDT Relays (sets of 2)
Sign In for Dealer Pricing
Sign In for Dealer Pricing
AS-A11-740-000-B|MA-ASA11740000B
Key Features
- Analog Aireshield
- Remote Sensor
- Add on Buzzer
Sign In for Dealer Pricing
Sign In for Dealer Pricing
CO2 5% VOL|MA-702900030
Key Features
- Carbon Dioxide CO2 Cal Gas Cylinder 17L 5% v/v (50,000 ppm) (M)
- Macurco recommends testing and calibration at a least once per year at a minimum but depending on the application and risk potential of the application a greater frequency might be needed.
- Used with Macurco Cal-Kit 4
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Shutdown up to 8 boilers individually via expansion relays
- 120VAC
- Customize up to 8 10A SPDT Relays (sets of 2)
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- 23 to 33 VDC
- Audible Tone: Adjustable to Continuous (high/low) or Temporal Four (high/low)
- Made in America
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- 19 to 33 VDC
- Strobe Candela: Adjustable at 15, 30, 75 or 110cd* (tested with clear lens cover)
- Strobe Flash Rate: One flash per second (20ms pulse duration)
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Shutdown up to 8 boilers individually via expansion relays
- 120VAC
- Customize up to 8 10A SPDT Relays (sets of 2)
Sign In for Dealer Pricing
Sign In for Dealer Pricing
Key Features
- Shutdown up to 8 boilers individually via expansion relays
- 24VAC/VDC
- Customize up to 8 10A SPDT Relays (sets of 2)